Axxius 800 - Release 2.2 3-11
Electrical Installation and Cabling
Chassis Connections
BITS Clock 1/BITS Clock 2
The external alarm connectors are three-pin wire-wrap connectors. One for each, Tip
(T), Ring (R) and Shield (S). Tip and Ring are the two connections for the 100 ohm
differential signal to the box. Shield is for grounding the shield of the clock cable to the
Axxius. If the customer is not using shielded cable, then only the Tip and Ring is
connected.
Bits Clock 1 and 2
back of Axxius
Przeglądanie stron 66