CLI Commands
set
reversion Set protection reversion on the DS3
off Disable protection reversion of loopback requests
on Enable protection reversion of loopback requests
threshold
Set defect thresholds for a DS3. Defaults for all are 0.
day Set threshold for a daily interval
ccv C-bit code violation range: 0 - 86400
ces C-bit errored seconds range: 0 - 86400
cses C-bit severely errored seconds range: 0 - 86400
lcv Line code violations range: 0 - 133401600
les Line errored seconds range: 0 - 86400
pcv Path code violations range: 0 - 133401600
pes P-bit errored seconds range: 0 - 86400
pses P-bit severely errored seconds range: 0 - 86400
sefs Severely errored frame seconds range: 0 - 86400
uas
Unavailable seconds range: 0 - 86400
min15 Set threshold for a 15 minute interval
ccv C-bit code violation range: 0 - 86400
ces C-bit errored seconds range: 0 - 86400
cses C-bit severely errored seconds range: 0 - 86400
lcv Line code violations range: 0 - 133401600
les Line errored seconds range: 0 - 86400
pcv Path code violations range: 0 - 133401600
pes P-bit errored seconds range: 0 - 86400
pses P-bit severely errored seconds range: 0 - 86400
sefs Severely errored frame seconds range: 0 - 86400
uas
Unavailable seconds range: 0 - 86400
unit Set the DS3 unit code PDML string
Command syntax: set {ds3-addr} unit {"string"}
{"string"} = transmission vendor’s identification, up to 6 characters,
enclosed in quotes.