Access Navigator - Release 1.8 August 2003 16-29
Maintenance Procedures
Install SIMM on Controller Card
Precautions
CAUTION! SERVICE DISRUPTIONS WILL OCCUR IF THE ACTIVE CONTROLLER CARD
IS REMOVED WITHOUT AN OPERATIONAL STANDBY CONTROLLER. TO AVOID SERVICE
DISRUPTIONS, ALWAYS REMOVE THE STANDBY CONTROLLER FIRST. IN A PROTECTED
SYSTEM WITH TWO CONTROLLER CARDS, THE ACTIVE CONTROLLER SHOULD BE
SWITCHED TO STANDBY MODE BEFORE REMOVING. IN AN UNPROTECTED SYSTEM WITH
ONLY ONE CONTROLLER CARD, SIMM INSTALLATION WILL DISRUPT SERVICE BUT WILL
NOT AFFECT STORED PROVISIONING DATA.
WARNING! THE ACCESS NAVIGATOR CONTAINS CIRCUIT CARDS AND COMPO-
NENTS THAT ARE SUBJECT TO DAMAGE BY ELECTROSTATIC DISCHARGE (ESD).
A
LWAYS FOLLOW THE STATIC-SENSITIVE EQUIPMENT HANDLING PROCEDURES ON
page 6-3 WHEN OPENING EQUIPMENT COVERS AND HANDLING PLUG-IN CIRCUIT CARDS.
Tools and Materials Required
Obtain the following tools and materials.
l Office records for installation site
l Screwdrivers, slotted
l Grounding wrist strap
l SIMM, 8 MB (included with software update 1.25)