Przeglądanie stron 7
10 Axxius 800 - Release 2.2
Quick Start
Assembly of Axxius 800
Assembly of Axxius 800
The cards should be positioned according to the following guidelines:
l Power Supply(s) 24 or 48 VDC
Single Power Supply - slot Power 1 or Power 2
Dual Power Supplies - slot Power 1 and Power 2
l Controller card(s) DS1 or DS3
Single Controller card - slot A1 or A2
Dual Controller cards - slot A1 and A2
l Interface card
The Interface card is designed with two boards that follow a single guide.
l Service Cards can be in any slot 1 through 8.
Note: Cards that use the front cable connections should be loaded from Slot 8
to 1. This will minimize card access issues due to cable interference.
l Relay Card in the Relay slot.
l Always install blank faceplates in any unused slots.
Controller
Interface
CardCards
(A1 & A2)
Service Card
Slots 1-8
Power
Supplies
(P1 & P2)
Future Development
Relay
Card